{"id":1953,"date":"2026-04-29T10:23:30","date_gmt":"2026-04-29T10:23:30","guid":{"rendered":"https:\/\/ntktrading.com\/su-toi-uu-cua-cac-san-pham-belimo-vao-cac-du-an-datacenter\/"},"modified":"2026-05-14T04:09:32","modified_gmt":"2026-05-14T04:09:32","slug":"su-toi-uu-cua-cac-san-pham-belimo-vao-cac-du-an-datacenter","status":"publish","type":"post","link":"https:\/\/ntktrading.com\/en\/news\/optimization-of-belimo-products-in-datacenter-projects\/","title":{"rendered":"Optimization of Belimo Products in Datacenter Projects"},"content":{"rendered":"<h2><strong>&#8220;Experience Maximum Uptime and Optimal Performance&#8221;<\/strong><\/h2>\n<p>For 50 years, Belimo has provided quality, reliable field devices for energy-efficient control of heating, ventilation, and air conditioning (HVAC) systems. With global expertise, scalable applications, and a leading market position, we have successfully delivered cooling solutions for data centers, where reliability and quality are paramount.<\/p>\n<p>We offer actuators, valves, sensors, and meters designed to ensure uninterrupted performance, optimal flow, independent system operation, and energy efficiency.<\/p>\n<p>The data center landscape is evolving, with next-generation GPUs requiring greater heat dissipation than ever. Traditional hot and cold aisle containment strategies struggle to remove enough heat for high-density racks. Belimo is ready with advanced data center cooling technologies, promoting more efficient liquid cooling systems that enhance thermal conductivity and reduce energy consumption.<\/p>\n<h3><strong>Belimo Products in Data Center Applications<\/strong><\/h3>\n<h3><strong>01. Chillers<\/strong><\/h3>\n<p>Butterfly valves with high-performance actuators for high flow rates.<\/p>\n<p>The central plant provides chilled water to the entire data center. Due to the significant cooling demands of modern data centers, this process requires high flow rates and, consequently, large-sized valves. Belimo butterfly valves, equipped with high-performance actuators, are perfectly suited for this application thanks to their high close-off pressure, minimal leakage, and IP66 rated enclosures (equivalent to NEMA 4), ensuring reliable operation even in harsh conditions.<\/p>\n<h3>02. CRAC<\/h3>\n<p>Electronic Pressure Independent Control Valves (EPIV) and sensors.<\/p>\n<p>CRAC stands for Computer Room Air Conditioning\u2014a system designed to control temperature, humidity, and air distribution in the data center. These refrigerant-based units are built to maintain precise environmental conditions, ensuring the protection and reliable operation of sensitive IT equipment.<\/p>\n<h3><strong>03. CRAH<\/strong><\/h3>\n<p>Electronic Pressure Independent Control Valves (EPIV) and sensors.<\/p>\n<p>Computer Room Air Handler (CRAH) units provide conditioned air to the IT equipment space (white space) in the data center. Belimo&#8217;s EPIV is a key component in CRAH systems, delivering precise and reliable water flow control. These valves play a vital role in maintaining optimal temperature and humidity in critical environments.<\/p>\n<h3><strong>04. Fan wall<\/strong><\/h3>\n<p>Damper actuators (EF and GK) on large damper banks.<\/p>\n<p>Belimo damper actuators are critical components in fan wall systems, providing precise airflow control to servers. Characterized Control Valves (CCV) and Electronic Pressure Independent Control Valves (EPIV) manage water flow through coils, ensuring efficient cooling and maintaining required supply air temperatures. Working in sync, these Belimo applications are essential for maintaining optimal environmental conditions for sensitive IT infrastructure.<\/p>\n<h3><strong>05. AHU<\/strong><\/h3>\n<p>Belimo Energy Valve\u2122, Electronic Pressure Independent Control Valves (EPIV), damper actuators, and sensors.<\/p>\n<p>Air Handling Units (AHU) deliver conditioned air to server spaces, technical rooms, and offices. These versatile units utilize Belimo\u2019s extensive product range to ensure proper airflow and water flow control. AHUs are also referred to as Computer Room Air Handlers (CRAH).<\/p>\n<h3><strong>06. Direct-to-Chip Cooling (Cold-plate)<\/strong><\/h3>\n<p>Belimo Energy Valve and differential pressure sensors for precise flow control in high-performance features.<\/p>\n<p>Direct-to-chip liquid cooling, commonly known as cold plate technology, is one of the most popular methods for cooling high-heat-output servers, such as those used in High-Performance Computing (HPC), Artificial Intelligence (AI), and Machine Learning (ML). The Belimo Energy Valve\u2122, along with differential pressure sensors, is the ideal choice for this application as it maintains a constant pressure drop across the entire rack. This ensures precise flow to each cold plate, even when a server is disconnected for maintenance.<\/p>\n<h3><strong>07. CDU<\/strong><\/h3>\n<p>Belimo Energy Valve, Characterized Control Valve (CCV), and Electronic Pressure Independent Control Valve (EPIV).<\/p>\n<p>Coolant Distribution Units (CDU) provide a water-glycol mixture to cool heat-generating equipment like servers. Belimo offers a comprehensive portfolio of CCV, EPIV, and Energy Valves perfectly suited for use in CDUs. These valves ensure precise flow control and can be easily adjusted as cooling demands change.<\/p>\n<h3><strong>08. Rear door heat exchanger<\/strong><\/h3>\n<p>Electronic Pressure Independent Control Valves (EPIV) and Characterized Control Valves (CCV) for precise flow control.<\/p>\n<p>Precise flow control is essential for the efficient operation of Rear Door Heat Exchangers (RDHx). Belimo EPIV and CCV provide reliable and accurate flow control, ensuring optimal performance for your RDHx system.<\/p>\n<h3><strong>09. Immersion cooling<\/strong><\/h3>\n<p>Electronic Pressure Independent Control Valves (EPIV) for precise flow control and Belimo Energy Valve for monitoring.<\/p>\n<p>Two-phase immersion cooling systems require precise water flow to ensure efficient condensation of the dielectric fluid. Belimo&#8217;s EPIV maintains stable flow to the coil, even with system pressure fluctuations. The Belimo Energy Valve\u2122 continuously monitors supply and return water temperatures, calculates thermal energy, and provides valuable analytics to help track cooling performance and detect inefficiencies.<\/p>\n<h3><strong>10. Power Generators<\/strong><\/h3>\n<p>Fail-safe actuators for combustion air control.<\/p>\n<p>Generators provide backup power to ensure continuous server operation during grid outages. Belimo&#8217;s fail-safe actuators are ideal for precise control of the combustion air required for these generators. The fail-safe feature ensures airflow can be closed immediately in the event of a fault. IP-rated options, such as IP66 (equivalent to NEMA 4), are available for installations outside the generator enclosure.<\/p>\n<h3><strong>11. Fire Protection Control<\/strong><\/h3>\n<p>Fire and smoke damper actuators to ensure safety during a fire.<\/p>\n<p>Belimo fire and smoke damper actuators are essential safety devices designed to protect data centers from fire and smoke hazards. These safety actuators are used to control fire and smoke dampers, often integrated into fire and smoke detection systems. In the event of a fire, they specifically prevent fire and smoke from spreading through ductwork, protecting people and infrastructure while playing a critical role in maintaining the operational continuity of mission-critical IT systems.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&#8220;Experience Maximum Uptime and Optimal Performance&#8221; For 50 years, Belimo has provided quality, reliable field devices for energy-efficient control of heating, ventilation, and air conditioning (HVAC) systems. With global expertise, scalable applications, and a leading market position, we have successfully delivered cooling solutions for data centers, where reliability and quality are paramount. We offer actuators, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1714,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1,175,176],"tags":[],"class_list":["post-1953","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-company-news","category-market-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/posts\/1953","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/comments?post=1953"}],"version-history":[{"count":1,"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/posts\/1953\/revisions"}],"predecessor-version":[{"id":1955,"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/posts\/1953\/revisions\/1955"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/media\/1714"}],"wp:attachment":[{"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/media?parent=1953"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/categories?post=1953"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ntktrading.com\/en\/wp-json\/wp\/v2\/tags?post=1953"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}